Input |
Frequency: |
10 MHz |
Level: |
7 dBm ±3 dB,
50 ohms |
Output |
Frequency: |
100 MHz |
Level: |
+13 dBm ±2 dBm, 50 ohms |
Stability |
Aging: |
±1 x 10-6/year after 30 days operating, typical
±5 x 10-7/year
thereafter |
Output Phase Noise:
Free Running |
100 Hz: -130 dBc/Hz
1 kHz - 158 dBc/Hz
10 kHz: -170 dBc/Hz |
Temperature: |
±5 x 10-7, 0 to +50șC, ref +25șC, free-running |
Harmonics: |
-30 dBc |
Sub-Harmonics: |
-50 dBc |
Non-Harmonics Spurious: |
-70 dBc |
Adjustment |
Loop Bandwidth |
Target Bandwidth: 30 Hz, type 2 |
|
Power Requirements |
Warm-Up Power: |
<10 watts at start-up for 5 min at +25șC |
Total Power: |
7 watts at steady state +25șC |
Supply Voltage: |
+15 VDC |
Phase Lock Alarm |
TTL |
Locked: +3.5 VDC to +5.2 VDC (Hi)
Out-of-lock: +0.8 VDC max (Lo) |
Phase Lock Voltage Monitor |
Voltage monitor pin
supplied |
Mechanical |
Crystal: |
SC-Cut |
Dimensions: |
2.25 x 3.10 x 0.72" |
Connectors: |
SMA and solder pins on side. Feed-thru terminals for lock
alarm, supply and phase lock monitor. |
Packaging: |
Machined aluminum enclosure or machined brass housing. |
|